DC/DC Converter
•
•
•
•
•
•
•
TEN 60 Series, 60 Watt
Wide 2:1 input voltage range
High efficiency up to 91%
No minimum load required
Over temperature protection
Under voltage lock-out circuit
Remote On/Off
UL 62368-1 IEC 62368-1
3-year product warranty
The TEN 60 series is a family of high performance 60W DC/DC converter modules with wide 2:1 input voltage ranges in a low profile case with industry-standard 2" x 2" footprint. High efficiency allows for an operating temperature
range of –40°C to 75°C. Built-in filters for both input and output minimizes the
need for external filtering. Further standard features include remote On/Off,
output voltage trimming, over voltage protection, under voltage lockout and
short circuit protection. Typical applications for these products are battery operated equipment and distributed power architectures in communication and industrial electronics.
Models
Order Code
Input Voltage
Output Voltage
Output Current
Efficiency
Range
nom. (adjustable)
max.
typ.
TEN 60-2410
3.3 VDC (2.97 - 3.63 VDC)
14'000 mA
89 %
TEN 60-2411
5 VDC (4.5 - 5.5 VDC)
12'000 mA
90 %
12 VDC (10.8 - 13.2 VDC)
5'000 mA
90 %
15 VDC (13.5 - 16.5 VDC)
4'000 mA
90 %
18 - 36 VDC
(24 VDC nom.)
TEN 60-2412
TEN 60-2413
TEN 60-2415
24 VDC (21.6 - 26.4 VDC)
2'500 mA
89 %
TEN 60-4810
3.3 VDC (2.97 - 3.63 VDC)
14'000 mA
89 %
5 VDC (4.5 - 5.5 VDC)
12'000 mA
91 %
12 VDC (10.8 - 13.2 VDC)
5'000 mA
90 %
15 VDC (13.5 - 16.5 VDC)
4'000 mA
90 %
24 VDC (21.6 - 26.4 VDC)
2'500 mA
90 %
TEN 60-4811
36 - 75 VDC
(48 VDC nom.)
TEN 60-4812
TEN 60-4813
TEN 60-4815
Options
TEN-HS3
- Optional Heat Sink: www.tracopower.com/products/ten-hs3.pdf
www.tracopower.com
September 20, 2023
Page 1 / 5
TEN 60 Series, 60 Watt
Input Specifications
Input Current
24 Vin models: 100 mA typ. (3.3 Vout model)
130 mA typ. (5 Vout model)
50 mA typ. (12 Vout model)
50 mA typ. (15 Vout model)
50 mA typ. (24 Vout model)
48 Vin models: 80 mA typ. (3.3 Vout model)
90 mA typ. (5 Vout model)
30 mA typ. (12 Vout model)
30 mA typ. (15 Vout model)
30 mA typ. (24 Vout model)
24 Vin models: 2'260 mA typ. (3.3 Vout model)
2'940 mA typ. (5 Vout model)
2'900 mA typ. (12 Vout model)
2'900 mA typ. (15 Vout model)
2'940 mA typ. (24 Vout model)
48 Vin models: 1'140 mA typ. (3.3 Vout model)
1'450 mA typ. (5 Vout model)
1'450 mA typ. (12 Vout model)
1'450 mA typ. (15 Vout model)
1'470 mA typ. (24 Vout model)
24 Vin models: 50 VDC max. (100 ms max.)
48 Vin models: 100 VDC max. (100 ms max.)
24 Vin models: 14.5 VDC min. / 15.5 VDC typ. / 17.5 VDC
max.
48 Vin models: 31 VDC min. / 32 VDC typ. / 35.5 VDC max.
24 Vin models: 6'300 mA (slow blow)
48 Vin models: 3'150 mA (slow blow)
(The need of an external fuse has to be assessed
in the final application.)
Internal Pi-Type
- At no load
- At full load
Surge Voltage
Under Voltage Lockout
Recommended Input Fuse
Input Filter
Output Specifications
Output Voltage Adjustment
See application note:
Voltage Set Accuracy
Regulation
Ripple and Noise
(20 MHz Bandwidth)
Capacitive Load
- Input Variation (Vmin - Vmax)
- Load Variation (0 - 100%)
3.3 Vout models:
5 Vout models:
12 Vout models:
15 Vout models:
24 Vout models:
3.3 Vout models:
5 Vout models:
12 Vout models:
15 Vout models:
24 Vout models:
Minimum Load
Temperature Coefficient
Start-up Time
Short Circuit Protection
Output Current Limitation
–10% to +20% (24 Vout models)
±10% (other output models)
(By external trim resistor)
www.tracopower.com/overview/ten60
Output power must not exceed rated power!
±1% max.
0.2% max.
0.5% max.
75 mVp-p typ.
75 mVp-p typ.
100 mVp-p typ.
100 mVp-p typ.
200 mVp-p typ.
36'000 µF max.
20'400 µF max.
3'550 µF max.
2'300 µF max.
885 µF max.
Not required
±0.02 %/K max.
20 ms max.
Continuous, Automatic recovery
150% typ. of Iout max.
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
September 20, 2023
Page 2 / 5
TEN 60 Series, 60 Watt
Overvoltage Protection
Transient Response
112 - 164% of Vout nom.
(depending on model)
3.7 - 5.4 VDC (3.3 VDC model)
5.6 - 7 VDC (5 VDC model)
13.8 - 17.5 VDC (12 VDC model)
16.8 - 20.5 VDC (15 VDC model)
30 - 33 VDC (24 VDC model)
8% max. (25% Load Step)
250 µs typ. (25% Load Step)
- Response Deviation
- Response Time
Safety Specifications
Safety Standards
EN 60950-1
EN 62368-1
IEC 60950-1
IEC 62368-1
UL 60950-1
UL 62368-1
www.tracopower.com/overview/ten60
PD 2
Not mains connected
- IT / Multimedia Equipment
- Certification Documents
Pollution Degree
Over Voltage Category
EMC Specifications
EMI Emissions
- Conducted Emissions
- Radiated Emissions
External filter proposal:
EMS Immunity
- Electrostatic Discharge
Air:
Contact:
- RF Electromagnetic Field
- EFT (Burst) / Surge
Ext. input component:
- Conducted RF Disturbances
- PF Magnetic Field
Continuous:
1 s:
EN 55032 class A (with external filter)
EN 55032 class B (with external filter)
EN 55032 class A (with external filter)
EN 55032 class B (with external filter)
www.tracopower.com/overview/ten60
EN 55024 (IT Equipment)
EN 55035 (Multimedia)
EN 61000-4-2, ±8 kV, perf. criteria A
EN 61000-4-2, ±6 kV, perf. criteria A
EN 61000-4-3, 10 V/m, perf. criteria A
EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±1 kV, perf. criteria A
KY 220 µF / 100 V
EN 61000-4-6, 10 Vrms, perf. criteria A
EN 61000-4-8, 100 A/m, perf. criteria A
EN 61000-4-8, 1000 A/m, perf. criteria A
General Specifications
Relative Humidity
Temperature Ranges
Power Derating
- Operating Temperature
- Case Temperature
- Storage Temperature
- High Temperature
Over Temperature
Protection Switch Off
- Protection Mode
- Measurement Point
Cooling System
Sense Function
95% max. (non condensing)
–40°C to +75°C
+110°C max.
–55°C to +125°C
Depending on model
See application note: www.tracopower.com/overview/ten60
120°C typ. (Automatic recovery at 100°C typ.)
Case
Natural convection (20 LFM)
10% max. of Vout nom.
(If sense function is not used, sense pins should
be connected to output pins.)
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
September 20, 2023
Page 3 / 5
TEN 60 Series, 60 Watt
Remote Control
- Voltage Controlled Remote
- Off Idle Input Current
- Remote Pin Input Current
Altitude During Operation
Switching Frequency
Insulation System
Isolation Test Voltage
Isolation Resistance
Isolation Capacitance
Reliability
Washing Process
Environment
- Input to Output, 60 s
- Input to Case, 60 s
- Output to Case, 60 s
- Input to Output, 500 VDC
- Input to Output, 100 kHz, 1 V
- Calculated MTBF
- Vibration
- Mechanical Shock
- Thermal Shock
Housing Material
Base Material
Potting Material
Pin Material
Pin Foundation Plating
Pin Surface Plating
Housing Type
Mounting Type
Connection Type
Footprint Type
Soldering Profile
Weight
Thermal Impedance
On: 3.0 to 12 VDC or open circuit
Off: 0 to 1.2 VDC or short circuit
Refers to 'Remote' and '-Vin' Pin
4 mA typ.
-0.5 to 1.0 mA
2'000 m max.
270 - 330 kHz (PWM)
300 kHz typ. (PWM)
Functional Insulation
1'600 VDC
1'600 VDC
1'600 VDC
1'000 MΩ min.
1'500 pF max.
410'000 h (MIL-HDBK-217F, ground benign)
According to Cleaning Guideline
www.tracopower.com/info/cleaning.pdf
MIL-STD-810F
7.7 g, 3 axis, random waveform, 60 min
MIL-STD-810F
50 g, 3 axis, terminal peak sawtooth, 11 ms
MIL-STD-810F
-55°C to +125°C, 72 cycles, 30 min each
Copper, Nickel plated
Non-conductive FR4 (UL 94 V-0 rated)
Epoxy (UL 94 V-0 rated)
Copper
Nickel (2 - 3 µm)
Tin (3 - 5 µm), matte
Metal Case
PCB Mount
THD (Through-Hole Device)
2" x 2"
Lead-Free Wave Soldering
265°C / 10 s max.
60 g
10.5 K/W typ.
8.4 K/W typ. (with Heat Sink)
www.tracopower.com/info/reach-declaration.pdf
REACH SVHC list compliant
REACH Annex XVII compliant
www.tracopower.com/info/rohs-declaration.pdf
Exemptions: 7a, 7c-I
(RoHS exemptions refer to the component
concentration only, not to the overall
concentration in the product (O5A rule).)
527286fc-5b1c-4797-b181-26e69d91a288
- Case to Ambient
Environmental Compliance - REACH Declaration
- RoHS Declaration
- SCIP Reference Number
Supporting Documents
Overview Link (for additional Documents)
www.tracopower.com/overview/ten60
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
September 20, 2023
Page 4 / 5
TEN 60 Series, 60 Watt
7
1
(0.400)
2
10.16
Bottom view
5.08
3
6
5
(0.50)
12.7
Pinout
8
(0.200)
5.08 7.62 5.08 7.62
7.62
(0.300) (0.200) (0.300) (0.200) (0.300)
50.8 (2.00)
Outline Dimensions
4
5.6
(0.22)
45.72 (1.800)
10.2
(0.40)
50.8 (2.00)
Pin
Single
1
+Vin (Vcc)
2
–Vin (GND)
3
Remote On/Off
4
–Sense
5
+Sense
6
+Vout
7
–Vout
8
Trim
Dimensions in mm (inch)
Pin diameter: 1.0 ±0.1 (0.04 ±0.004)
Tolerances: x.x ±0.5 (x.xx ±0.02)
x.xx ±0.25 (x.xxx ±0.01)
© Copyright 2023 Traco Electronic AG
Specifications can be changed without notice.
www.tracopower.com
Rev. September 20, 2023
Page 5 / 5